Farey, A Treatise on the Steam Engine (1827): engine ratings and blowing engines
Books A Treatise on the Steam Engine
Source John Farey, A Treatise on the Steam Engine, Historical, Practical, and Descriptive,
vol. 1 (London, Longman et al., 1827; the only volume published), archive.org id
treatiseonsteame01fareuoft (University of Toronto copy, 798 PDF pages, OCR layer present).
Pages every page below is the printed page. PDF page = printed page + 18 (printed 62 is PDF 80,
printed 574 is PDF 592, printed 724 is PDF 742). The table on p. 574 was read from the page image; the
OCR scrambles it.
Purpose the period rating of Boulton and Watt rotative engines and the proportions of their
double-acting blowing cylinders with a receiver.
Conventions a line marked INFERRED is arithmetic on figures in this file, not Farey's text. Farey's
"strokes per minute" are double strokes (one up, one down): "25 strokes per minute" of a 4 ft stroke is
"200 feet per minute" (p. 489), so piston speed = 2 x stroke x strokes. Units are Farey's (inches, feet,
pounds, cubic feet); the metric column is mine (1 in = 25.4 mm, 1 ft = 0.3048 m, 1 psi = 6.895 kPa,
1 cu ft = 28.3 l, 33,000 ft-lb/min = 745.7 W). OCR fractions I could not check against an image are
recomputed from the areas Farey prints and marked (area).
Other details on the pages read
- p. 456: "The cylinder is supported upon two cross beams XX, which are worked into the side walls at each end"; the page states no material.
- p. 491: "The connecting-rod is made of cast iron 5 3/8 inches by 3 3/4 inches, with the angles taken off; it is about 12 1/4 feet long" (10 hp engine; image).
- p. 597 and 599 (PDF 617, whose header the OCR reads as 590): "the bridle rods must move about two studs or centre pins, which are fixed to the spring beams, one at each side of the piston rod"; the bridles hang on a horizontal axis under the spring beams (p. 597). p. 590 is the steam-pipe and safety-valve rule.
1. Horse-power and how Boulton and Watt rated an engine
| figure | value | metric | page | quote |
|---|---|---|---|---|
| Origin of the unit | Watt's experiment on London brewers' horses, 1784 | 438 | "a horse of that kind, walking at the rate of 2 1/2 miles per hour, could draw 150 pounds ... at the rate of 220 feet per minute" | |
| Horse-power | 33,000 lb raised 1 ft in a minute (528 cu ft of water) | 745.7 W | 438, 66 | "equal to that of raising 528 cubic feet of water (or a weight of 33 000 pounds) to a height of one foot in a minute" |
| Real horse | 22,000 ft-lb/min, 8 h a day | 439 | "22 000 lbs., raised at the rate of 1 foot per minute, may be taken for a real horse-power" | |
| Rated against the horse | "30 horses to act in concert, to perform the work of a 20 horse-power engine" | 439 | the rating is "a determined measure of mechanical power ... without any direct reference to the actual power of horses" | |
| Rating pressure | effective load rather than 7 psi | 48 kPa | 439 | "the effective pressure on the piston was taken at rather less than 7 pounds per square inch" |
| Piston speed | 200 to 256 ft/min by size | 61 to 78 m/min | 439 | "the piston will move through a space of from 200 to 256 feet per minute, according to the size of the engine" |
| Steam per hp | 33 cu ft of cylinder volume a minute | 0.93 m3/min | 439, 573 | "33 cubic feet per minute for each horse-power, reckoning only by the space actually occupied by the piston" (no allowance for the clearance at the ends) |
| Standard load | 6.944 psi per sq in; 5.454 per circular inch | 47.9 kPa | 440, 575 | "If an engine expends 33 cubic feet of steam per minute for each horse-power, the effective pressure on the piston will be 6.944 lbs. per square inch" |
| Power rule | hp = d^2 (in) x v (ft/min) x P (psi) / 42,017 | 440 | "multiply the square of the diameter of the cylinder, in inches, by the motion of the piston, in feet, per minute; multiply the product by the effective pressure ... and divide the latter product by 42 017" | |
| Cylinder rule | d^2 = hp x 6050 / v | 575 | "Multiply the number of horse power by the constant number 6050; divide the product by the motion of the piston, in feet per minute, and the square root of the quotient is the proper diameter for the cylinder" | |
| What the rating means | the effect at the end of the fly-wheel axis, friction not deducted from the rating | 573 | "the power which is exerted at the extremity of the axis of its fly-wheel, and therefore the power actually exerted by the piston must be greater" | |
| Why 7 and not 10.5 | allowance for engines not kept in best order | 573 | "it was judged advisable ... to make a very ample allowance for the probability of their not being kept in the best order, and therefore the load was only assumed at about 7 pounds" | |
| Nominal against indicated | a good engine overcomes 1 1/2 times its rating, 1 2/3 with boiler steam at 4 to 4 1/2 psi | 486, 576 | "capable of working effectually, and at their full speed, when they are loaded with a resistance which requires half as much more as their nominal horse-power"; "a 20 horse engine can exert 30 horse power; a 40 horse engine 60 horse power" | |
| Indicator at the limit | 10 3/4 psi effective after 2 psi friction (12 3/4 unbalanced) | 74 kPa | 486 | "the unbalanced pressure against the piston will be (9 + 3 3/4 =) 12 3/4 pounds per square inch; and deducting 2 pounds for the friction of the engine, there is full 10 3/4 lbs. effective pressure" |
| Indicator at the rating | 7 psi effective, 1 1/2 psi friction; condenser vacuum 27 in Hg; steam 2 psi under atmosphere in the cylinder | 487 | "leaves 7 lbs. per square inch effective pressure to impel the machinery, which is according to Mr. Watt's standard" | |
| Boiler steam | 1 to 1 1/2 psi above atmosphere suffices at the rating; 2 1/2 psi to blow the condenser through | 487 | "it is needless to keep up the steam to more than 1 or 1 1/2 lb. per square inch above the pressure of the atmosphere" | |
| Speed ceiling | about 220 ft/min with Watt's valve areas | 67 m/min | 595 | "the motion of the piston cannot advantageously be made greater than about 220 feet per minute" (valve area one-27th of the piston) |
| Short strokes | rating scales with speed | 595 | "if the 10 horse-engine ... were to be worked at the rate of 30 strokes per minute, it would then exert 12 horse-power, without any extra force" | |
| Post-1800 makers | larger bores for the same name | 575 | "a 20 horse engine acquired a cylinder 25 inches diameter; a 30 horse, 30 inches; a 40 horse, 33 inches; a 50 horse, 37 inches; a 60 horse, 40 inches; an 80 horse, 45 inches; and a 100 horse engine, a cylinder of 50 inches" | |
| Shorter strokes by Boulton, Watt and Co. later | 40 hp now 32 1/2 in x 6 ft; 80 hp 44 1/2 in x 7 ft | 575 | "Messrs. Boulton, Watt, and Co.'s 40 horse engine is now made with a cylinder 32 1/2 inches diameter, and 6 feet stroke ... their 80 horse engine, with a cylinder 44 1/2 inches diameter, and 7 feet stroke" | |
| Coal | 10 1/2 lb/hp-h average, 9.07 at best; 14 lb for a worn 6 hp class | 488 | "each horse-power will require 9.07 lbs. of such coals per hour"; "10 1/2 lbs. of coals per hour" (84 lb bushel, Newcastle) | |
| Coal by size | 40 hp 4 bushels an hour (8.4 lb/hp-h); 50 hp 4.8 bushels (8.06 lb/hp-h) | 573, 517 | "This engine consumed about 4 bushels of good Newcastle coals per hour (= 336 lbs.)"; "8.06 pounds of coals per hour to each horse-power" | |
| Boiler per hp | 10 sq ft of heating surface in Watt's time, 12 in later practice; grate 3/4 sq ft | 580-584 | "it appears 12.1 square feet to each horse-power, say 12 square feet"; "two-thirds, or three-fourths of a square foot of fire-grate, to each horse-power" | |
| Water evaporated | 1.165 cu ft per hp-hour | 33 l | 577 | "1.165 cubic feet evaporated per hour for each horse-power" |
2. Boulton and Watt rotative engines
2a. The scale (p. 574, Table of the dimensions of the cylinders and velocities of the pistons)
Farey: the table "has been formed from the three standard engines of 10, 20, and 40 horse-power mentioned by Mr. Watt; the other sizes being calculated according to the same proportion"; the rows marked * match engines he met (4 to 30 hp wooden framing, 36 hp upwards lever wall, p. 501 note and p. 456). Bore in inches (area in sq in), stroke in feet, double strokes a minute, piston feet a minute, steam cu ft a minute, effective psi, cu ft per hp, load in lb. The metric bore is mm.
| hp | bore | stroke | strokes/min | ft/min | steam cu ft/min | psi | stroke / bore |
|---|---|---|---|---|---|---|---|
| 4 | 12 (305 mm) | 3 | 29 | 174 | 135 | 6.8 | 3.0 |
| 6* | 14 (356) | 3 1/2 | 27 | 189 | 202 | 6.82 | 3.0 |
| 8* | 16 (406) | 4 | 24 | 192 | 268 | 6.84 | 3.0 |
| 10* | 17 1/2 (445) | 4 | 25 | 200 | 334 | 6.86 | 2.7 |
| 12* | 19 (483) | 4 | 25 | 200 | 400 | 6.88 | 2.5 |
| 14 | 20 5/8 (524) | 4 | 25 | 200 | 465 | 6.91 | 2.3 |
| 16 | 21 3/4 (552) | 4 1/2 | 23 | 207 | 531 | 6.91 | 2.5 |
| 18 | 23 (584) | 4 1/2 | 23 | 207 | 598 | 6.91 | 2.3 |
| 20* | 23 3/4 (603) | 5 | 21 1/2 | 215 | 662 | 6.92 | 2.5 |
| 24* | 26 (660) | 5 | 21 1/2 | 215 | 794 | 6.92 | 2.3 |
| 26* | 26 3/4 (679) | 5 1/2 | 20 | 220 | 861 | 6.92 | 2.5 |
| 30* | 28 1/4 (718) | 6 | 19 | 228 | 993 | 6.92 | 2.5 |
| 36* | 30 7/8 (784) | 6 | 19 | 228 | 1192 | 6.92 | 2.3 |
| 40* | 31 1/2 (800) | 7 | 17 1/2 | 245 | 1324 | 6.92 | 2.7 |
| 45* | 33 1/3 (845) | 7 | 17 1/2 | 245 | 1490 | 6.92 | 2.5 |
| 50 | 35 1/8 (892) | 7 | 17 1/2 | 245 | 1650 | 6.94 | 2.4 |
| 60 | 38 1/2 (978) | 7 | 17 1/2 | 245 | 1980 | 6.94 | 2.2 |
| 80 | 43 1/2 (1105) | 8 | 16 | 256 | 2640 | 6.94 | 2.2 |
| 100 | 48 5/8 (1235) | 8 | 16 | 256 | 3300 | 6.94 | 2.0 |
The stroke / bore column is INFERRED (stroke in inches over bore). Four rows of the printed table are omitted above: 22 hp (25 in, 5 ft, 21 1/2, 215 ft/min, 728 cu ft), 28 hp (27 7/8 in, 5 1/2 ft, 20, 220, 927), 70 hp (40 3/4 in, 8 ft, 16, 256, 2310) and 90 hp (46 1/8 in, 8 ft, 16, 256, 2970). The cu ft per hp column falls from 33.7 (smallest) to 33.0 (largest). Quote, p. 574: "It appears from this table that Mr. Watt assumed the expenditure of steam by each size of engine, to be very nearly proportionate to the power exerted by it". Two ratings of one bore: "The 50 horse engine was at first made with a cylinder 34 inches diameter, and 8 feet stroke ... and afterwards with a cylinder 36 inches diameter, and 7 feet stroke; but ultimately an engine of the last dimensions was rated at 53 horse-power" (p. 574). Stroke and bore: "In the 20 horse-engine, which is usually considered as a standard, the length of the stroke (5 feet) is 2 1/2 times the diameter of the cylinder"; "in the large engines, above 50 horse-power, the stroke is shorter than 2 1/2 times the diameter" (p. 594). Watt's own first statement (p. 440): "A 10 horse double rotative engine, was made with a 17 1/2 inch cylinder, the length of its stroke 4 feet, and to make 25 strokes per minute"; the 20 hp "23 3/4 inc. diam., the piston making a 5 feet stroke, and working at the rate of 21 1/2 strokes per minute"; the 40 hp "31 1/2 inches diameter, the piston made a 7 feet stroke, and went at the rate of 17 1/2 strokes per minute". The first London brewery engines were single-acting, "24 inches diameter, the length of stroke 6 feet, and they made 18 strokes per minute; these were about 10 horse-power" (p. 440).
2b. The four measured engines (sun-and-planet; Farey measured them in 1805)
| item | 10 hp, 1795 (p. 489-491) | 20 hp, 1792 (p. 495-498) | 30 hp, 1798 (p. 500-502) | 40 hp, 1792 (p. 502-504) |
|---|---|---|---|---|
| bore | 17 1/2 in (445 mm); bored to 18 1/4 later | 24 in (610) | 28 1/4 in (area) | 31 1/2 in (area) |
| stroke, strokes/min, ft/min | 4 ft, 25, 200 | 5 ft, 21, 210 | 6 ft, 19, 228 | 7 ft, 17 1/2, 245 |
| steam cu ft/min (per hp) | 334 (33.4) | 660 (33) | 993 (33.1) | 1326 (33.15) |
| effective psi (mean) | 6.86 | 6.944 | 6.93 | 6.92 |
| mean piston force, lb | 1650 | 3142 | 4344 | 5390 |
| utmost piston force | 11 lb per circular inch, 3369 lb | 6336 lb | 8778 lb | 10,915 lb |
| great lever (beam), oak | 13 1/3 ft between joints, 16 1/2 in deep x 12 broad | 16 ft, 19 deep x 16 1/2 | 18 1/2 ft, 24 deep x 19 | 21 1/2 ft, 28 deep x 20 |
| connecting rod | cast iron 5 3/8 x 3 3/4 in, 12 1/4 ft | cast iron 5 in sq, 15 ft | oak 10 x 9 with cast foot, 18 ft | oak 11 x 10 with cast stem, about 20 ft |
| sun and planet | each "rather less" / "rather more" than 2 ft, 31 and 33 teeth, 2.36 in pitch, 4 in broad | each about 2 3/4 ft (OCR unreliable; 42 teeth at 2 1/2 in pitch), 5 in broad | each 3 ft, 39 teeth, 2.9 in pitch, 5 1/2 in broad | each 3 1/2 ft, 44 teeth, 3 in pitch, 6 in broad |
| fly-wheel | 12 ft diameter, rim 5 1/2 x 2 1/2 (13 3/4 sq in), 1557 lb rim, 48 1/2 rpm | 14 ft, rim 6 x 6, 4770 lb, 42 rpm | 16 ft, rim 8 x 4, 4815 lb, 38 rpm | 18 ft, rim 9 x 5, 7623 lb, 35 rpm |
| flywheel axis | cast iron 5 1/2 in sq, 4 1/2 ft between bearings | 6 3/4 in sq, 5 ft | 8 in sq, 5 ft | 9 1/2 in sq, 6 ft |
| air pump bore, stroke | 12 in, under 2 ft (OCR) | 15 in, 2 1/2 ft | 19 in, 3 ft | 21 in, 3 ft |
| condenser | "the same size as the air-pump" | not given | not given | not given |
| cold water pump | 5 1/2 in, 2 ft | 11 1/2 in, 2 1/2 ft | 10 in, 2 ft | 10 in, 2 1/2 ft |
| valve apertures | 3 3/4 in dia., 8.9 sq in, 0.89 sq in/hp | 4 1/2 in, 17 sq in, 0.85 | 5.1 in, 24 sq in, 0.8 | not given |
| coal | about 1 1/4 bushels/h | 2 to 3 bushels/h | 3 1/2 to 4 cwt/h | about 4 bushels/h (p. 573) |
| frame | wood | wood | wood or lever wall (p. 500 note) | masonry lever wall |
Quotes: 10 hp "The fly-wheel Q is 12 feet diameter outside ... The fly-wheel makes 48 1/2 revolutions per minute when the piston makes 25 strokes per minute" (p. 491); 20 hp "The great lever is an oak beam 16 feet long, from centre to centre" (p. 497); 30 hp "The great lever is 18 1/2 feet long" (p. 501); 40 hp "The great lever is an oak beam, 21 1/2 feet long between the centres of the joints at each end" (p. 503). Fractions of the 20 and 30 hp beam depth and the 10 hp air-pump stroke are OCR readings; the 30 and 40 hp bores are recomputed from the printed areas (area). The 10 hp beam is 13 1/3 ft by the image (3.33 stroke, not the 3 1/12 rule; the engine was "not made at Soho", p. 489).
Boulton and Watt's pump rules (p. 592): "the diameter of the air-pump to be two-thirds of the diameter of the cylinder, that is, four-ninths of the area; but the motion of the air-pump bucket being only half as great as that of the piston ... the effective capacity of the pump will be only four-36ths, or one-ninth of that of the cylinder." Cold water pump "one-24th part of the capacity of the steam cylinder" (p. 592); injection about 0.6 cu ft/min per hp (p. 593-594).
2c. The lengths rule (pp. 596-599)
| figure | value | page | quote |
|---|---|---|---|
| Beam length | 3 1/12 x stroke between joint centres | 596 | "that length will be 3 1/12 times the length of the stroke; or 3 feet 1 inch for every foot of the stroke" |
| Cylinder to crank axis | 3 x stroke, a whole number of feet | 596 | "the horizontal distance between the vertical centre line of the cylinder ... and that of the centre of the axis of the crank, exactly three times the length of the stroke ... because ... that distance must be set out by the masons" |
| Beam vibration | 1 in per foot of stroke (1/12) | 596 | "will deviate from the vertical line, one-12th of the length of the stroke" |
| Beam radius | 18 1/2 in per ft of stroke | 596 | "The radius of the great lever ... must then be 1 5/12 of the length of the stroke, that is, 18 1/2 inches, for every foot of the stroke" |
| Beam swing | 37.85 deg over the stroke | 597 | "The angular motion of the great lever about its centre will be 37.85 degrees, during the whole stroke" |
| Main and back links | about 3/7 of the stroke (Watt), 1/2 modern | 599 | "Mr. Watt's practice was to make them about three-sevenths of the length of the stroke" |
| Parallel and bridle rods | bridle = parallel rod = half beam radius, back-link joint halfway out | 598 | "the bridle rod C D must be of the same length as the parallel rod D E, and also equal to half the radius A B, of the great lever" |
| Connecting rod | not important; often equal to the beam, 3 x stroke | 599 | "often made the same length as the great lever, or three times the length of the stroke of the piston" |
| Fly-wheel diameter | sun-and-planet: rather less than 3 x stroke; on a second axis smaller; on the crank axis 3 to 4 x stroke | 599 | "commonly made rather less than three times the length of the stroke of the piston" |
| Sun and planet | pitch diameters each half the stroke (sum = stroke), same teeth | 614 | "the geometrical diameters of the wheels ... must be equal to half the length of the stroke made by the piston" |
| Sun and planet speed | two fly-wheel turns a stroke | 641 | "giving a double velocity to the fly-wheel ... requires to be only one-fourth the weight" |
| Stroke ratio | no fixed rule; "advantageous to proportion an engine with as great a length of stroke ... as can be conveniently used" | 594-595 |
2d. Fly-wheel energy (pp. 637-642)
| figure | value | page | quote |
|---|---|---|---|
| Rim energy / half-stroke work | 3 to 3 3/4 over 2 to 100 hp; 3.2 Boulton, Watt and Co. standard | 638, 640 | "the energy of the rim of the fly-wheel is usually between 3 and 3 3/4 times the power exerted during half a stroke" |
| Measured here | 10 hp 3.13, 20 hp 4.16, 30 hp 2.67, 40 hp 3.14 | 491, 498, 502, 504 | |
| Rolling mill | 30 to nearly 50 x, with an extra wheel | 639 | "the energy of the whole being from 30 to near 50 times the power exerted in half a stroke" |
| Rim iron | 450 lb/cu ft, 9.817 lb per 1 sq in x 3.1416 ft | 638, 642 | |
| Arms | about two-thirds the weight of the rim | 641 | |
| Rule for rim | cu ft = hp / strokes x 2,760,000 / (D x rpm)^2 | 640 | "The quotient is the requisite quantity of cast iron in cubic feet, to form the rim" |
2e. The 50 hp Albion Mills engine (pp. 509-517, 1786 to 1789) and later forms
34 in bore, 8 ft stroke, 16 strokes (256 ft/min), 7.1 psi, 50 hp, two fly-wheels (p. 509-510): "The cylinder was 34 inches diameter ... The length of the stroke of the piston was 8 feet, and in regular working it was intended to make 16 strokes per minute". Coal 4.8 bushels an hour (p. 517). The 1797 50 hp distillery engine and the 1808 36 hp engine (Plates XIX and XX, p. 695: "The foundations are entirely of stone ... The great lever is made of cast iron ... a simple crank, in lieu of sun and planet-wheels, and a multiplying-wheel") are described by Farey but their dimensions were not digested here.
3. Blowing engines for iron furnaces
| figure | value | metric | page | quote |
|---|---|---|---|---|
| First double-acting blowing cylinder, 1777 | steam cylinder about 30 in, blowing cylinder about 36 in, at the opposite end of the beam; air to a floating-piston regulating cylinder | 762 and 914 mm | 328 | "a steam cylinder of about 30 inches diameter, and at the opposite end of the great lever, a blowing cylinder, or air pump, of about 36 inches diameter. This cylinder being closed at both ends ... blew out the air, both in ascending and descending ... This was the first application of the double acting air pump, or blowing cylinder for furnaces: it is now the universal practice" |
| Carron machine, water-driven | 1272 cu ft/min compressed to 17.2 psi absolute (2.5 gauge) | 36 m3/min | 284 note | "which blew 1272 cub. ft. of air, compressed to an elasticity of 17.2 lbs. per squ. inc." |
| Smeaton's 1770s furnace | four blowing cylinders 54 in x 4 1/2 ft, 18 strokes a minute, 1286 cu ft a minute, nose-pipe 4 in; fire engine 30 in x 6 ft lifting water to the wheel | 280 | ||
| Beaufort, 1780 | four cylinders 60 in x 4 1/2 ft (88 cu ft each), 2112 cu ft a minute, nose-pipe 3 1/2 in; fire engine 36 in x 6 1/2 ft | 281 | ||
| Atmospheric engine blowing direct, 1784 | blowing cylinder loaded to blow on the return stroke; "regulating cylinder" floating piston | 281-283 | "the blowing cylinder was adapted to blow twice as much air at every stroke, as the nose-pipe would discharge into the furnace during the time of that stroke" | |
| Scottish engine, about 1790 | steam 40 in (44 in as found, 1819) x 6 ft; blowing cylinder 60 in x 6 ft, single-acting, loaded 2.77 psi; regulating cylinder 96 in x 6 ft (2 1/2 x blowing capacity), floating piston 2.63 psi; 15 to 18 strokes; 117.8 cu ft a stroke; 1600 cu ft/min net; conduit 12 in; power 19.6 hp for one furnace | 283-285 | "The blowing cylinder of 60 inches diam. and 6 feet stroke, would take in 117.8 cubic feet of air at every stroke, and it usually made from 15 to 18 strokes per minute" | |
| Water regulator, 1794 | "now become the universal practice"; chest inverted in a water cistern, a 5 to 6 ft water head | 286 | "the chest forms a vast magazine of compressed air, from which the water will expel as much as is necessary to supply the blast" | |
| Derbyshire engine with water regulator, about 1797 | steam 48 in x 6 ft, 12 strokes; blowing cylinder 72 in x 6 ft (inverted, closed top); air chest circular, 15 ft diameter, capacity "about six or seven times as great as that of the blowing cylinder"; 15 in air pipe; three branches to the chest | 287-288 | "Steam-cylinder 48 inc. diam., the piston making a 6 ft. stroke, and about 12 strokes per minute. The blowing cylinder 72 inc. diam. and 6 ft. stroke" | |
| Devon works, 1796 air chamber | atmospheric 48 1/2 in, blowing cylinder 78 in, same stroke; rock vault 72 x 14 x 13 ft = 13,100 cu ft "about 84 times the capacity of the blowing cylinder"; pressure 5 in of mercury (2.45 psi); abandoned for regulating cylinders (damp) | 289 | "To regulate the blast, a large vault or air-chamber was excavated in the rock" | |
| Boulton and Watt blowing engine, Plate XXV, about 1807 | steam cylinder 48 in x 8 ft; blowing cylinder 84 in x 8 ft, double-acting; same beam and parallel motions; air pump 31 in (OCR 31 1/2) x 4 ft; piston rod 4 3/4 in; steam valves 9 in | 1219 mm and 2134 mm | 724 | "The cylinder is 48 inches diameter, and the piston makes a stroke of 8 feet ... The blowing cylinder N, is a double forcing-pump of 84 inches diameter, and its piston makes a stroke of 8 feet, the same as the steam piston" |
| Plate XXV valves and pipes | four branches, three valves each, each aperture 8 x 14 1/2 in; 348 sq in a branch; conduit pipe 21 in = 1/4 of the bore (1/16 of the area); 51 ft/s through the suction valves | 725-726 | "the conduit-pipe P is 21 inches diameter, or one-fourth of the diameter of the cylinder; consequently the area of the pipe is one-16th of the area of the cylinder" | |
| Plate XXV speed | usually 12 strokes of 8 ft = 192 ft/min; full speed 16 strokes | 725, 727 | "The engine usually makes 12 strokes per minute of 8 feet length, and then the motion of the piston is 192 feet per minute" | |
| Plate XXV blast | 3 psi, "usually makes 12 strokes per minute, and blows two furnaces"; at 16 strokes "capable of blowing three furnaces" | 20.7 kPa | 727 | "when the operation of the furnaces requires the compression of the air to be 3 pounds per square inch, the engine usually makes 12 strokes per minute, and blows two furnaces" |
| Plate XXV delivery | cylinder 38.48 sq ft; 298.2 cu ft a half stroke taken in (7 3/4 ft stroke); 286 cu ft actually discharged a half stroke; 6864 cu ft/min of common air, 517 lb a minute; 5700 cu ft/min at 17.7 psi absolute | 194 m3/min | 727-728 | "286 cubic feet actually discharged at each half stroke, or x 24 = 6864 cubic feet of common air blown per minute into the two furnaces" |
| Leak and clearance | each end space about 12 cu ft; 1/20 lost by leakage | 727 | "(deduct) -1/20th to allow for the loss by leakage through the piston and valves" | |
| Plate XXV nozzles | each furnace two nose pipes of about 2 1/2 in; four apertures 19.64 sq in; cupola two pipes of 1 3/4 in (2.45 sq in) | 64 mm | 728 | "It is usual to blow the air into the great smelting furnaces through nose pipes of about 2 1/2 inches diameter; each furnace has two such pipes" |
| Plate XXV load | steam piston load 9.2 psi when the blast is 3 psi; 85.2 hp for two furnaces and a cupola | 728 | "The resistance or load on the steam piston is at the rate of 9.2 pounds per square inch, when the resistance to the blowing piston is 3 lbs. per square inch" | |
| Plate XXV regulator | inverted cast-iron chest 36 x 14 x 8 ft, "nearly 30 tons"; cistern 45 x 23 ft at top, 10 ft deep; water 5 1/2 ft deep at rest, about 2 ft in the chest working, depressed 7 ft (3 psi); trapped air 3780 cu ft, "about 12.3 times the capacity of the blowing cylinder" | 726-727 | "The inverted chest is 36 feet long by 14 feet wide, and 8 feet high; it is made of plates of cast iron screwed together, and its weight is nearly 30 tons" | |
| Regulator purpose | the cylinder pauses at each half-stroke end, so the blast "is not continuous" | 726 | "there is an instant at the termination of each half stroke, when no air is blown by the cylinder" | |
| Piston | cast-iron disc with radial ribs, 5 in deep edge, cup-leather rings both faces bolted by cast segments; no valves in it | 726 | "The blowing piston is a circular plate of cast iron, with a rim round the outer edge" | |
| Valves | thick leather hung from the top plate, iron plates riveted on, hinge by the leather bending | 725 | "The air valves of the blowing cylinder are made of thick leather, fortified by iron plates riveted upon the leather" | |
| Cylinder | cast in two lengths bolted by a mid-height flange, bottom and top flanged, stuffing box in the cover | 724 | "The blowing cylinder is formed in two lengths N N, which are united by flanges in the middle of its height" |
Period blast and ratios (read off the rows above)
| engine | blast, psi | blow bore / steam bore | blow stroke / steam stroke | receiver / blowing cylinder capacity |
|---|---|---|---|---|
| Wilson House 1777 | not given | 36 / 30 = 1.2 (INFERRED) | opposite end of the beam, same stroke | one regulating cylinder "of about the same size" |
| Scottish 1790 | 2.77 | 60 / 40 = 1.5 (INFERRED) | 1 | 2 1/2 (cylinder) |
| Derbyshire 1797 | about 2.2 to 2.6 (5 to 6 ft head) | 72 / 48 = 1.5 (INFERRED) | 1 | 6 to 7 (air chest) |
| Devon 1796 | 2.45 | 78 / 48 1/2 = 1.6 (INFERRED) | 1 | about 84 (rock vault) |
| Plate XXV 1807 | 3 | 84 / 48 = 1.75 (INFERRED) | 1 | 12.3 |
Receiver construction (pp. 286-288, 726-727)
Inverted cast-iron chest of bolted plates standing on blocks 1 1/2 ft above the cistern floor; the air pipe crosses over it with vertical branches into the top (not into the bottom) so the same air goes in and out each stroke and the damp air at the water stays; a loaded masonry top or stone ballast, because "it would float when the water is expelled from it by the air" (p. 287); the water must never reach the pipe branches, "an explosion would be produced" (p. 288). Water head for 3 psi is 7 ft (p. 727); the Derbyshire chest has a 5 to 6 ft head (pp. 286, 287). Conduit bore is 1/4 of the cylinder bore (Plate XXV, 21 in on 84, p. 725). The suction side takes air at about 16 x the piston speed (p. 726).
4. Gaps
- Farey gives no nominal horse-power for a blowing engine: Plate XXV is described by its cylinder, stroke, blast and the computed 85.2 hp load (p. 728), not by a rating. Its 48 in x 8 ft cylinder is near the table's 100 hp row (48 5/8 x 8 ft x 16 strokes).
- The table's 4 ft stroke is the 10 to 14 hp rows (17 1/2 to 20 5/8 in); no engine of 30 in bore and 4 ft stroke is in Farey.
- No beam length, fly-wheel or air pump for any table row other than the four measured engines (10, 20, 30, 40 hp) and the Albion 50 hp (partly read); the 36 hp (p. 695-708), 50 hp distillery (p. 517-520) and 12 hp are not digested.
- The condenser of the measured engines is stated only for the 10 hp ("the same size as the air-pump"); no bore for the condensing cistern.
- No trunnion height, no beam weight, no receiver size for a rotative blowing engine other than the Plate XXV chest (the others are atmospheric engines).
- Receiver size for a given blowing cylinder is not in Farey; only the ratios above. Overman's period ratio is not in this book (see the Overman blowing note).
- Blast pressures in Farey are 2.4 to 3 psi at the furnace; no pressure above 3 psi is given for any blowing engine in this volume (he notes "3 pounds" as the higher case, p. 727).
- OCR fractions: the 20 hp sun and planet diameter ("2 1/4" in the text, 2 1/2 by the 42 teeth at 2.5 in pitch: 42 x 2.5 / 37.7 = 2.8 ft by Farey's own p. 615 rule, so the OCR is unreliable); the 10 hp air pump stroke; Plate XXV air pump bore (31 1/2).
- The 12 hp row of the p. 574 image gives 19 in (area 283.5 sq in = 19.0 in), not 19.7 in.