Rankine, Wilson, Truran, Bauerman, Percy and Kirk on the draught of a chimney and the stack heights of the iron furnaces
Books A Manual of the Steam Engine and Other Prime Movers, A Treatise on Steam Boilers, The Iron Manufacture of Great Britain, A Treatise on the Metallurgy of Iron, Metallurgy: Iron and Steel, The Cupola Furnace, The Manufacture of Iron
Sources:
- W. J. M. Rankine, A Manual of the Steam Engine and other Prime Movers (London, 1859). No text layer. Printed page = PDF page - 30. The formulas were read on the page images (PDF 316-318) and the text on archive.org's OCR; Articles 232-233 are printed pp. 284-290, the furnace losses pp. 292-293.
- R. Wilson, A Treatise on Steam Boilers (London, 1873). No text layer; read from archive.org's OCR text, printed pages from the running heads. Chapter XIII (Combustion of Coal, from p. 254 on) and XIV (Smoke Prevention and Firing) are in the volume and carry no chimney draught formula and no chimney height: Wilson's only figures are the air per lb of coal and the escaping gas temperature (below). The draught rule is Rankine's.
- W. Truran, The Iron Manufacture of Great Britain (London, 1862). Printed page = PDF page - 26.
- H. Bauerman, A Treatise on the Metallurgy of Iron (1870 printing). Printed page = PDF page - 12.
- J. Percy, Metallurgy: Iron and Steel (London, 1864). No text layer; archive.org's OCR text, pages from the running heads.
- W. Kirk, The Cupola Furnace (1892, American; Ireland's cupola is English, about 1856). Printed page = PDF page - 24. Outside 1840-1880 as a book; the one figure used from it that is English describes a cupola of 1856.
- F. Overman, The Manufacture of Iron (1851), for two figures.
The other notes on the iron furnaces were searched for "chimney" and "stack": none carries a stack height; the note on Overman's blowing says outright that its range has no 33 ft stack.
Conversions: 1 ft = 0.3048 m, 1 lb = 0.4536 kg, 1 lb/sq ft = 47.88 Pa, 1 in of water = 249.1 Pa. Cells marked COMPUTED are this note's arithmetic on the book's formula, not a book figure.
The rule (Rankine, Articles 232-233)
Rankine states the draught as the head, the height of a column of the hot gas in the chimney whose weight equals the pressure that moves the gas, and converts it to an inch of water for a siphon gauge. The terms:
| Symbol | Meaning | Unit | Value or source |
|---|---|---|---|
| H | height of the chimney above the grate | ft | the design figure |
| h | head: draught pressure as a height of hot gas | ft of hot gas | eq 8 or 4 |
| T2, tau2 | external air, absolute | F + 461.2 | 50 F gives 511.2 |
| tau1 | gas in the chimney, absolute | F + 461.2 | the design figure |
| tau0 | freezing point, absolute | F | 32 F = 493.2 (Rankine writes the 32 deg ordinate) |
| V0 | volume at 32 F of the air supplied per lb of fuel | cu ft | 150, 225, 300 for 12, 18, 24 lb of air a lb of fuel (p. 286) |
| A | sectional area of the chimney | sq ft | for a conical chimney, the area at the top (p. 287) |
| u | velocity of the gas | ft/s | eq 4 |
| w | weight of fuel the furnace can completely burn | lb | eq 5 |
| l, m | length of chimney plus flue; hydraulic mean depth, area / perimeter (a quarter of the diameter, round or square) | ft | p. 287 |
| f | friction coefficient on sooty surfaces (Peclet) | - | 0.012 |
| G | resistance of grate and fuel bed (Peclet; furnaces burning 20 to 24 lb of coal per sq ft of grate) | - | 12 |
The equations as printed (Rankine pp. 285-289):
- Volume of the gas at a temperature T: V = V(32 F) x (T + 461.2) / 493.2 (p. 286, with a table of cubic feet a lb of fuel for 12, 18 and 24 lb of air from 3275 F down to 32 F; the furnace gas is taken equal in volume to the air supplied, the hydrogen's steam being neglected).
- Density of the discharged gas, eq 3: D = (tau0 / tau1) x (0.0807 + 1 / V0) lb per cu ft; "from 0.084 to 0.087 x tau0 / tau1". 0.0807 lb per cu ft is air at 32 F.
- Head and velocity (Peclet's formula "confirmed by practical experience"), eq 4: h = (u^2 / 2g) x (1 + G + f l / m); with the constants, eq 4A: h = (u^2 / 2g) x (13 + 0.012 l / m). g = 32.174 ft/s^2.
- Fuel burned, eq 5: w = u A tau0 / (V0 tau1). Rankine first defines w "per second", and ends the paragraph "per hour"; the per-second reading is the one that fits the units.
- Head as pressure, eq 6: p = h D lb per sq ft; in inches of water, eq 7: 0.192 p = 0.192 h (tau0 / tau1) (0.0807 + 1 / V0) ("the multiplier is 1 / 5.204 = 0.192").
- Head a chimney gives, eq 8: h = H [0.96 (tau1 / tau2) - 1], and the height for a given head, eq 9: H = h / [0.96 (tau1 / tau2) - 1]. The 0.96 is 0.0807 / (0.0807 + 1 / V0) for 24 lb of air a lb of fuel (V0 = 300: 0.0807 / 0.0840). "The head produced by the draught of a chimney is equivalent to the excess of the weight of a vertical column of cool air outside the chimney, and of the same height, above that of a vertical column of equal base, of the hot gas within the chimney."
- Best temperature, eqs 10-11 (p. 289): the weight of gas discharged goes with the velocity, which goes with the root of (0.96 tau1 - tau2), times the density; it is greatest when tau1 / tau2 = 25 / 12 (a ratio of 2.083), and then h = H. "The density of the hot gas is one-half of that of the external air." Rankine's example: external air 50 F (511.2 absolute), gas for the best draught 1065.0 absolute, "603.8" F, "a little below the temperature of melting lead"; the rule: "to insure the best possible draught through a given chimney, the temperature of the hot gas in the chimney should be nearly, but not quite, sufficient to melt lead". With 24 lb of air a lb of fuel, 650 cu ft of hot gas a lb of fuel at that temperature.
- A chimney too hot is not cooled with cold air but by using the heat (steam, water heating); "it is never advantageous to raise the temperature in the chimney above that limit" (p. 289).
- Cost: with the fire about 2400 F above the air and the chimney gas about 600 F above it for the best draught, "under no circumstances can it be necessary to expend more than one-fourth of the total heat of combustion for the purpose of producing a draught by means of a chimney"; "by making the chimney of large enough dimensions as compared with the grate, a much less expenditure of heat than this may be made to produce a draught sufficient for the rate of combustion" (pp. 292-293).
- Air for combustion: chimney draught needs 24 lb of air a lb of fuel, "the weight of air required for dilution is equal to that required for combustion" (Rankine, in the article before 232, printed p. 284 by the OCR; Wilson p. 254 the same, 24 lb); "with very powerful chimney, or artificial draught" Wilson takes one and a half times the minimum, 18 lb a lb of fuel (p. 254). A blast pipe or fan needs no chimney heat.
Worked examples
Rankine gives the best-draught temperature but no printed number for a given height; these are this note's use of eqs 3, 4A, 5, 7 and 9, not book figures. V0 = 300 (24 lb air a lb of fuel), outside air 50 F.
| Case | Calculation | Result | Source |
|---|---|---|---|
| Gas at the best temperature (604 F), H = 100 ft | h = H [0.96 x 1065.2 / 511.2 - 1] = 100.0 ft of hot gas; D = (493.2 / 1065.2) x 0.0840 = 0.0389 lb/cu ft; p = 3.89 lb/sq ft; x 0.192 | 0.75 in of water; 186 Pa for 30.5 m (6.1 Pa a metre) | COMPUTED from eqs 3, 7, 8 |
| The same, gas at 500 F, H = 100 ft | h = 80.5 ft of hot gas, D = 0.0431 | 0.67 in of water; 166 Pa | COMPUTED |
| Puddling stack, H = 36 ft, 604 F | h = 36.0 ft; p = 1.40 lb/sq ft | 0.27 in of water; 67 Pa for 11.0 m | COMPUTED |
| The same at 500 F | h = 29.0 ft | 0.24 in of water; 60 Pa | COMPUTED |
| Fuel a flue of 24 in square can burn: H = 36 ft, 604 F, l = 36 + 20 ft of flue (assumed), m = 0.5 ft | u = sqrt(2g h / (13 + 0.012 x 56 / 0.5)) = 12.7 ft/s; w = u A tau0 / (V0 tau1) with A = 4 sq ft | 0.0785 lb/s = 282 lb/h = 128 kg/h | COMPUTED from eqs 4A, 5 |
The last row is of the order of Bauerman's puddling furnace burning "from 1 1/2 to 2 cwt. per hour" (168 to 224 lb/h, 76 to 102 kg/h) on a grate of 7 to 8 sq ft (p. 267). It leaves out Truran's contraction of the flue to about a third of its area at the roof, which cuts the figure. Peclet's G = 12 holds for furnaces burning 20 to 24 lb of coal a sq ft of grate.
Rates of combustion with chimney draught (Rankine p. 285)
| Rate, lb of coal a sq ft of grate an hour | Case |
|---|---|
| 4 | the slowest in Cornish boilers |
| 10 | ordinary, Cornish |
| 12 to 16 | ordinary, factory boilers |
| 16 to 24 | ordinary, marine boilers |
| 20 to 23 | quickest complete combustion of dry coal, air through the grate only |
| 24 to 27 | quickest of caking coal, with air holes above the fuel (area one-sixteenth of the grate) |
| 40 to 120 | locomotives, blast pipe or fan |
Wilson p. 258: the gases leave the boiler at 400 to 700 F and "seldom less than 25 per cent" of the heat goes up the chimney (the escaping gas of the best draught, 604 F above, is inside that range).
The rule for height against grate and fuel
Neither Rankine nor Wilson prints a table of chimney height against grate area. The rule is the formula: the height H and the gas temperature fix the head h; the head fixes the velocity u through the resistance of the flue and grate (eq 4A); the area A of the chimney and u fix the fuel burned (eq 5). Rankine's statements:
- "By making the chimney of large enough dimensions as compared with the grate, a much less expenditure of heat ... may be made to produce a draught sufficient for the rate of combustion" (p. 293): height or area can buy draught.
- A conical chimney counts as a prism of its top area (p. 287).
- The temperature in a chimney "may often be reduced with advantage considerably below that corresponding to the most effective draught", provided the heat taken out is used, as long as the draught still burns the fuel (p. 289).
The books give these empirical figures:
| Rule | Value | Source |
|---|---|---|
| Boiler grates, 15 lb a sq ft an hour, "easily maintained by having a chimney-stack from 110 to 120 feet high, when the grate surface is 180 to 200 square feet" | 33.5 to 36.6 m for 16.7 to 18.6 m2 of grate; 2700 to 3000 lb of coal an hour (1.2 to 1.4 t) | Truran 117 (PDF 143) |
| Flue to stack sectional area, puddling | one-fifth of the grate for bituminous coal, one-seventh for anthracite | Bauerman 267 (PDF 279) |
| Stack for a single puddling furnace | "from 30 to 50 feet high, and about 20 inches square"; when several flues are led into one, "especially when a part of the heat is taken away by passing the flame under steam boilers, it is necessary to increase the height to 100 feet or more, in order to overcome the additional resistance" | Bauerman 267-268 (PDF 279-280) |
| Draught cannot be had through a deep bed | "A chimney cannot draw through a high column of coal an amount of air sufficient to give it the requisite heat"; anthracite needs blast | Overman p. 278 (PDF 278), printed page not read |
| Heating furnace needs a hot, tall stack | "The rapid draught necessary to the production of an intense heat can be produced only by a chimney stack of the requisite height, maintained at a comparatively high temperature. If it be cold, the drawing power is reduced to a minimum"; a boiler or other conductor in the stack reduces it | Truran 239-240 (PDF 265-266) |
| Damper cools the stack | a damper at the foot of the stack opens it to a column of cold air when shut, and the stack is slow to recover | Truran 239 (PDF 265) |
| Mill furnace draws harder than the puddling furnace | "The mill-furnace being always the hottest has a stronger draught than the puddling furnace" (Percy, on boilers heated by the waste heat of both; the informant and works names are garbled in the OCR) | Percy 691 |
Stack heights by furnace
| Furnace | Stack height | In SI | Other figures | Book and page |
|---|---|---|---|---|
| Puddling furnace | 30 ft above the cast-iron framework, 36 ft altogether, "for the generality of forge coals" | 9.1 m above the frame, 11.0 m | flue 24 in square inside, contracted at the furnace roof to about a third of that area (17 x 9 in for a coal near anthracite, 18 x 18 in for a more inflammable one); walls 1 brick for 14 ft, 1 brick for 10 ft, 1/2 brick the last 6 ft; damper at the top, worked by lever and chain | Truran 207 (PDF 233) |
| Puddling furnace | 30 to 50 ft, about 20 in square, one furnace to a stack | 9.1 to 15.2 m | 100 ft or more when several flues are led to one stack past boilers | Bauerman 267-268 |
| Puddling and reheating furnaces on boilers (Dowlais) | 150 ft, 12 ft square, flues carried in culverts of about 60 sq ft | 45.7 m | boilers away from the forge; "no chimneys whatever in the forge" | Percy 692 (Menelaus's letter) |
| Reheating (balling, heating, mill) furnace | "has a chimney of like dimensions" to the puddling furnace's | as puddling: 36 ft, 11.0 m | the furnace is 8 or 9 in wider and 2 ft longer; fireplace area about 12 sq ft; a damper at the foot of the stack in some works | Truran 226 (PDF 252), 239 (PDF 265) |
| Reheating furnace | no height; its flue slopes to the stack; "a small fire is usually placed in front of the stack both in reheating and puddling furnaces" | - | a second fireplace at the flue end for plates | Bauerman 312-313 (PDF 324-325) |
| Crucible (steel melting) furnace | "about 40 feet high, in order to command a strong draught", same section as the furnace | 12.2 m | melting hole 3 ft deep, 1.5 to 2 ft square, a short flue near the top into the stack; several furnaces to one stack | Bauerman 356 (PDF 368) |
| Cupola, English, c. 1856 (Ireland's) | 25 ft from the bottom plate to the top of the stack, 12 ft to the sill of the charging door | 7.6 m; 3.7 m; 3.9 m of stack above the sill | casing 50 in to the door, 2 ft 3 in at the top; blast, so not a chimney draught | Kirk 157 (PDF 181) |
| Cupola (Ireland's, bottom tuyere) | 27 ft to the top, 12 ft to the sill | 8.2 m; 4.6 m above the sill | 4 ft 6 in to the door, 2 ft 6 in at the top | Kirk 159 (PDF 183) |
| Cupola, the stack where the foundry is shut in | "from a few feet above the foundry roof to twenty or thirty feet" | 6.1 to 9.1 m | the stack "must be made of sufficient height to give the necessary draught for lighting up in all kinds of weather"; a contracted stack draws well and throws sparks, an enlarged one draws poorly "unless it is very high" | Kirk 5 (PDF 29) |
| Blast furnace waste gas, boiler stack | 80 ft, 6 ft in diameter, "an overpowering draught" | 24.4 m | gas through and under the boiler, 120 ft of flue; 4 times through | Percy 467 |
| Boiler battery (reference) | 110 to 120 ft for 180 to 200 sq ft of grate at 15 lb a sq ft an hour | 33.5 to 36.6 m | - | Truran 117 (PDF 143) |
| Converting (cementation) furnace | "conical chimney, forty or fifty feet high", to lead the smoke above the roof | 12.2 to 15.2 m | furnace 12 or 15 ft wide, 20 or 25 ft deep | Overman (PDF 477), printed page not read |
Reading the figures
- The cupola's stack is a collar, not a chimney that draws: it takes the cupola's own blast (Kirk pp. 5, 157, 159). Its height above the charging door is 13 to 15 ft (4 to 4.6 m) in Ireland's examples, and Kirk's "twenty or thirty feet" above the roof is the limit, where the stack is the draught for lighting up.
- The reheating furnace has no figure of its own beyond "like dimensions" (Truran p. 226), so its height is the puddling furnace's, about 36 ft (11.0 m), with the mill furnace drawing harder (Percy p. 691). The first-hand gap is that no book here prints a reheat height.
- The crucible furnace's 40 ft (12.2 m) is the tallest of the single-furnace stacks, with the smallest grate.
- The books give no drop for a cold stack beyond Truran's description of its effect; Rankine's rule gives h = 0 at the air's own temperature (0.96 tau1 / tau2 = 1 at tau1 / tau2 = 1.042, about 21 F above the air).
- Rankine's coefficients are Peclet's for coal grates of 20 to 24 lb a sq ft an hour; a charcoal or coke bed, or a grate burning 10 lb, has no figure in these books.