Steam and boilers
as of 0.8.0
A boiler burns coal under a water vessel and forces the steam into a pipe network. One litre of water becomes 16 L of steam. Steam temperature follows the line's pressure:
steam temperature = 100 C * (pressure + 1) ^ 0.25
which is 100 C on an unpressurised line, about 150 C at 4 atm and about 157 C at the 5 atm a Cornish Boiler holds.
The chain is always the same: water feeds a boiler, the boiler drives an engine, the engine turns one sub-machine. This page is the boiler and the water; see Steam engines and sub-machines for the other half and Pipe networks and pressure for the plumbing.
The Cornish Boiler
| Quantity | Value |
|---|---|
| vessel capacity | 1600 L |
| water needed before it will boil | 300 L |
| water it will hold and boil | up to 1000 L |
| steam output at full rate | 64 L/s |
| choke pressure | 5.0 atm |
| exhaust made while burning | 16 L/s |
| draw of one chimney on the exhaust run | 16 L/s |
| exhaust back-pressure that chokes the fire | 0.8 atm |
| time a choked fire burns before it goes out | 10 s |
| heating time before it boils | 180 s |
| explosion radius | 3 blocks |
It is raised by right-click construction: place the block, then hold right-click on it with the stage's tool in the main hand (the riveting set, and a trowel after it for the last two stages) and its materials in the hotbar to take it through its stages. It brings its own brickwork, grate and hatches; there is nothing to wall in around it. The whole build is 22 metal plates, 8 rods, 32 rivets and 44 fire bricks, and it reserves a volume 3 wide, 6 long and 3 high, less the corners of the top course.
Rivets, not nails. A riveted seam is the one joint that is both strong and tight, and no stage of a pressure vessel accepts anything else.
Firing it
The boiler answers on two hatches.
- The main hatch is the firing door at the near end. Hold right-click with an empty hand to swing it, right-click coal into the open door to charge the grate, and hold right-click on a charged grate to light it.
- The man hatch is the cover on top of the barrel. Hold right-click to swing it, then pour water in from a bucket or bail it back out.
The grate holds four courses of four, so 16 units of a single fuel, and the fill is readable on the block as it burns down. Anything whose burn temperature is 1000 C or more is admitted. What separates fuels is mostly how long a charge lasts, not how hot it burns: the boiler is limited by its heating surface, so any fuel at 1200 C or above raises steam at the vessel's full rate. A cooler fuel runs at
rate = (flame temperature - steam temperature) / (1200 C - steam temperature)
which also stretches the 180-second heating time in the same proportion.
Water
The vessel is primed by hand through the man hatch. Filling from a stack of buckets fills one bucket's worth and wastes the rest, so pour one bucket per slot, or pump.
The automatic intake, the pipe port on the left of the firing door as you face it, draws from a feed network at up to 20 L/s and stops at half the vessel's capacity, which is 800 L. Hand pouring is not capped by that and can reach the 1000 L boiling ceiling.
Pressurised feedwater is dangerous. Every litre admitted above 1 atm flashes an extra litre of steam per atm of feed pressure, which spikes a boiling vessel toward a burst. Gate or throttle any pumped feed.
Water reaches a boiler through one of two pumps. The Manual Fluid Pump is hand-cranked, needs no engine, and moves 2 L/s at 1 atm as long as a working Fluid Intake feeds its input line; the crank support in its model marks the input side. The engine-driven Feed Pump is a sub-machine and moves far more; see Steam engines and sub-machines.
Venting and bursting
A burning boiler makes 16 L/s of exhaust, and its fire draws only through draught: a vanilla chimney on the exhaust run, or a built siex Smoke Stack on that run. The chimney stands on the open top face of a pipe passthrough, straight or bend, and one chimney draws 16 L/s, which is the whole of what the boiler makes. An unpiped exhaust port gives no draught, and neither do open pipe ends, however many there are.
The Cornish Boiler's exhaust port faces sideways, so a Pipe Outlet set against it with a chimney on top draws nothing. Run a pipe from the port to a passthrough or a bend with a chimney on its open top, or to a smoke stack.
Without draught the boiler is choked. Its look-at line reads "Choked: no draught! The exhaust needs a chimney or a smoke stack." and the fire is put out after 10 seconds. An exhaust run backed up to 0.8 atm chokes it the same way.
On the steam side, a boiler that keeps firing with nowhere to send its steam sits at its choke pressure and explodes after 30 seconds there. The emergency release is the man hatch, which vents about 200 L/s. An unpiped steam outlet only leaks at 16 L/s, which is nowhere near enough to save an over-pressured vessel.
A burst shatters every block within 3 blocks whose resistance is under 20, which takes pipes, ports, coal piles and soft terrain and leaves other machines standing, and scatters 0.4 of the boiler's construction materials. Mining a boiler intact returns 0.8 of them instead.
A Cornish Boiler's 5 atm ceiling sits above the Watt Beam Engine's 4 atm breaking point. A pressure valve between the two, with an overflow, is not optional.
Step by step
- Place a Fluid Intake on a pond, on a full cube of water at least 3 blocks deep, with no other intake within 6 blocks.
- Raise a Cornish Boiler and pipe its exhaust port, at the far corner, to a pipe passthrough, straight or bend, whose top face is open, and stand a vanilla chimney on that top face.
- Pipe the intake to a Manual Fluid Pump and the pump's output into the boiler's feed port, on the left of the firing door, or pour by hand, one bucket per slot.
- Get at least 300 L into the vessel.
- Open the main hatch, charge the grate with one fuel, and hold right-click to light it. Shut both hatches.
- Wait about three minutes for it to start boiling.
- Pipe the steam outlet, on top of the barrel, to whatever is consuming steam, through a Piping (Pressure Valve) gated below the consumer's breaking pressure.
What goes wrong
The fire keeps going out. The boiler is choked. Either the exhaust run has no chimney or smoke stack on it, or the exhaust is backed up to 0.8 atm. An open pipe end is not draught: pipe the exhaust to a chimney on a passthrough's open top, or to a smoke stack. A chimney on a Pipe Outlet beside the port draws nothing.
The boiler will not start. It holds less than 300 L, or the man hatch is open and the steam is going straight out of it.
It boils slowly. The fuel burns below 1200 C. Lignite, the only common one, burns at 1100 C and so runs at about 0.90 of the rate, which stretches the 180-second heat-up to about 200 seconds. It is a 10% penalty, not a different order of machine.
It exploded with a safety valve fitted. Check that the valve's output has somewhere to go. A pressure valve with nothing piped past it vents, which works; a pressure valve whose output run is already at the same pressure moves nothing at all, because gas only goes downhill.
It exploded straight after a relog or a server restart. This one is carried over from the mod line this code came from, where several players saw a boiler at critical pressure immediately after a chunk reload with safety valves fitted and the hatch open. No fix is recorded and it has not been re-tested here. Until it has been, vent the boiler and stop the run before a restart.
Filling from a stack of buckets lost most of the water. Pour one bucket per slot, or use a pump.
Planned
This section is planned and not yet in the game; until it lands, the rules above apply.
Pressure ratings
The Cornish Boiler comes in two plate builds, normal plate and boilerplate. The 5 atm ceiling above is replaced: normal plate chokes at 4 atm and boilerplate at 6 atm, and the pressure gauge reads full at its own build's ceiling. The first boiler is the normal-plate build, paid in ordinary plate. The boilerplate build is its upgrade, paid in boilerplate rolled from the steam hammer's slab, and opens with the steam hammer. Both are riveted, and rivets come only from the riveter, so the first boiler waits for the rolling mill and the riveter.
| build | chokes at | against the rest of the line |
|---|---|---|
| normal plate | 4 atm | at the Watt Beam Engine's breaking point |
| boilerplate | 6 atm | above the cast main's 5 atm burst rating, under the cast small pipe's 8.75 atm |
A boiler piped to a cast main still holds that run at 5 atm, no higher. A safety valve set at 5 atm or lower guards the main on a boilerplate run. The pressure valve before the engine stays necessary: the boiler's ceiling is well above what the engine takes.
Stop valve and safety valve
A stop valve stands on the steam riser. Its handwheel is turned by right-click. A new boiler stands open. Shut, no steam leaves the boiler, not even through an open pipe end, so the pressure rises. The man hatch is still the emergency release.
The boiler front carries a blank flange where a safety valve fits. The valve is an upgrade: a boiler starts without one, and right-clicking the flange with the valve in hand fits it. It sits on the shell, never behind the stop valve, so the stop valve cannot cut it off. Its lever carries a ball with seven marked notches, and the ball's place sets the pressure the valve blows at:
- notch 0 blows at 3.0 atm, and each notch out from there adds 0.5 atm, up to the notch at the build's own rating
- right-click with an empty hand moves the ball one notch out, sneak right-click one notch in; the ball stops at the build's rating
- the valve blows at up to 128 L/s, twice the boiler's full steam rate, and reseats 0.05 atm under its setting
- the block's readout gives the setting ("blows at 4.0 atm") and "Blowing off" while it vents
A wrench takes the valve off again and puts the blank flange back, but only under 0.5 atm; above that the boiler must be blown down first. The valve comes back as an item.


Damper
A damper plate in the exit duct has its handle on the boiler front, east of the firing door. Right-click with an empty hand shuts it a quarter, sneak right-click opens it a quarter, and the readout gives its place: shut, 1/4, 1/2, 3/4 open or open. Steam rate and exhaust both scale by one factor, 0.35 shut and 1 open. A fire banked with the damper shut makes steam at 0.35 of the rate and lasts 1 / 0.35 times as long, about 2.9 times, which is how a fireman keeps a bed he cannot use yet.
Ports and gauge
The feed pipe enters at the top front, over the firing door, in place of the left-hand port, so a pipe runs clear of a player standing at the door. All three ports are drawn in their pipe's size: feed and steam are cast small, the exhaust a plated main. The feed check valve is the boiler's own, on the feed nozzle, so a boiler refuses backflow when its feed stops.
The steam gauge first on a boiler is a closed-air mercury gauge: a glass tube sealed at its top, standing in a small iron cistern of mercury piped to the steam space. The steam presses the mercury up the tube against the air trapped above it, and a scale beside the tube is marked at each atmosphere. It reads low pressures plainly and the ceilings coarsely. The dial gauge is its upgrade, a needle sweeping evenly to full scale. The mercury comes from the retort furnace.
Feeding a boiler under steam
The automatic intake that stops at 800 L goes. The water level becomes the player's: feed enters as fast as the valve on the feed line is opened, and the player sets it to the rate steam is drawn, reading the gauge glass and the try cocks, which become working parts. The level drifts when the draw changes. Filling a cold boiler through the man hatch stays as it is. A low-pressure boiler fed from a raised cistern takes a float valve. Pressurised feed no longer flashes extra steam; feed instead takes heat from the fire, and warmer feed makes more steam from the same coal: at 4 atm, feed at 90 C gives about 12% more than feed at 20 C, hot condensate at 40 C about 3%. A masonry economiser at the boiler's flue exit warms feed that way.
Low water is the boiler's failure, not over-pressure: an opening in the steam line blows the boiler down rather than bursting it. A fusible plug in the furnace crown melts when the water falls too low, and the steam puts the fire out. The player fits a new plug. Without one, low water ruins the boiler, and feed pumped onto the hot plate explodes it. A low-water valve, an upgrade fitted like the safety valve, gives warning first: its float opens it as the water nears the furnace crown, and it blows loudly before the plug melts.
Four devices feed a boiler:
| device | works when | note |
|---|---|---|
| manual fluid pump | the boiler is cold | against pressure a man's sustained work gives about 0.3 L/s at 3 atm, falling as pressure rises |
| feed pump | the engine is turning | costs the engine's one sub-machine slot |
| mechanical pump | the wheel turns, fire lit or not | needs no engine; two tiers, wooden on the vanilla mechanical network and cast on mpenergy |
| injector | any steam pressure | live steam, no moving parts |
The injector is a cast block with three cast small ports: live steam on top, cold water on one side, delivery on the other, and an open overflow bore straight down. It delivers above the pressure of the steam driving it. A handwheel on its water branch has five notches, 0 to 4; it picks up when the notch suits the steam, and the overflow runs when it does not. It will not pick up on hot feedwater. A second cast small steam port on the boiler, with its own cock, takes the injector's steam pipe.

The boiler's intake will take feed only at or above its own pressure, so a pump must deliver more than the boiler holds. Every pump carries a stroke counter that gives its strokes a minute and the flow they make; a stalled pump counts no strokes. The Watt's feed pump has none of its own and is read on the counter on the Watt's beam.
The feed pump on the engine carries no masonry: its barrel's flange rests on a cast bed ring at grade, and the well below is the player's to line. Its barrel is bored at the boring machine alone, so the first feed pump waits for it.

